Semiconductor

Functional Safety in Embedded Systems: IEC 61508 and Hardware Requirements

Industry Inspire Editorial Team Published Oct 24, 2026 Updated Oct 24, 2026 5 min read

Embedded systems increasingly perform functions that can affect:

  • people,
  • machinery,
  • environment.

Examples include:

  • emergency shutdown,
  • burner control,
  • motor protection,
  • process safety.

When failure can create unacceptable risk, the system may need to be designed according to functional-safety principles.

IEC 61508 is the foundational international standard for functional safety of:

electrical/electronic/programmable electronic safety-related systems.

Fundamentals and Technology Overview

What Is Functional Safety?

Functional safety means the system responds correctly to:

  • inputs,
  • failures,
  • dangerous conditions

so that risk remains acceptable.

Safety Function

A safety function is a specific action intended to reduce risk.

Example:

If pressure exceeds limit, close valve.

Safety Integrity Level

IEC 61508 defines:

  • SIL 1,
  • SIL 2,
  • SIL 3,
  • SIL 4.

Higher SIL means stricter integrity requirements.

Hardware Random Failures

Hardware can fail due to:

  • semiconductor defects,
  • aging,
  • memory errors,
  • electrical stress.

The safety design must detect or tolerate dangerous failures.

Systematic Failures

These result from:

  • design mistakes,
  • software bugs,
  • specification errors.

Functional safety addresses both:

  • random,
  • systematic

failure causes.

IEC 61508 Revision Status

IEC 61508 is undergoing a major 2026 revision.

IEC has released pre-release versions of the third edition, including:

  • IEC 61508-1:2026,
  • IEC 61508-2:2026,
  • IEC 61508-3:2026.

A new semiconductor-focused part, IEC 61508-2-1:2026, specifically addresses semiconductor development and integration requirements.

Semiconductor Requirements

IEC 61508-2-1 outlines expectations for:

  • semiconductor development processes,
  • software test libraries,
  • soft IP,
  • integration constraints,
  • deliverables to system integrators.

This is especially relevant for MCU and SoC vendors.

Safe State

Every safety design should define what happens when a dangerous condition is detected.

Examples:

  • de-energize motor,
  • close valve,
  • disable heater.

Fault Detection

Hardware diagnostics may include:

  • watchdog,
  • ECC,
  • RAM test,
  • Flash CRC,
  • clock monitor,
  • voltage monitor.

Watchdog

An independent watchdog detects:

  • software hang,
  • stalled execution.

Implementation, Testing, and Optimization

ECC

ECC memory can detect and correct certain memory faults.

Lockstep CPU

Some safety processors use dual CPU cores executing the same instructions.

Differences between results indicate a possible hardware fault.

Clock Monitoring

A clock monitor detects:

  • stopped oscillator,
  • invalid frequency.

Voltage Monitoring

Brownout and supply monitoring protect against unsafe execution during undervoltage.

Memory Test

Boot-time or runtime self-test can detect memory faults.

CPU Self-Test

Diagnostic libraries may test:

  • registers,
  • ALU,
  • control logic.

FMEDA

Failure Modes, Effects and Diagnostic Analysis evaluates:

  • component failure modes,
  • failure rates,
  • diagnostic coverage.

FMEDA is a core hardware-safety analysis method.

Diagnostic Coverage

Diagnostic coverage measures how effectively safety mechanisms detect dangerous faults.

Safety, Security, and Reliability

Safe Failure Fraction

SFF measures the proportion of failures that are either:

  • safe,
  • detected dangerous failures.

Hardware Fault Tolerance

Some SIL targets require the architecture to tolerate one or more faults depending on:

  • subsystem type,
  • diagnostic coverage,
  • failure assumptions.

Redundancy

Redundant channels can reduce the chance of a single failure causing a dangerous outcome.

Diversity

Redundant systems may use diverse:

  • sensors,
  • processors,
  • software

to reduce common-cause failure.

Common Cause Failure

Two redundant channels are not independent if one environmental event can disable both.

Examples:

  • shared power supply,
  • shared clock,
  • shared software defect.

Independence

Safety functions may need separation from non-safety functions.

This can include:

  • memory isolation,
  • power-domain separation,
  • independent watchdog.

Safety MCU

A safety-oriented MCU may provide:

  • ECC,
  • lockstep CPU,
  • hardware self-test,
  • safety documentation.

Safety Manual

The semiconductor vendor may provide a safety manual defining:

  • assumptions,
  • constraints,
  • required diagnostics.

System integrators must follow these conditions.

Diagnostic Libraries

Vendors may provide libraries that test:

  • CPU,
  • RAM,
  • Flash,
  • peripherals.

The new semiconductor-focused IEC 61508-2-1 explicitly addresses software test libraries supplied with semiconductors.

Proof Testing

Some safety systems require periodic tests to reveal hidden failures.

Safety Lifecycle

IEC 61508 uses a lifecycle approach covering:

  • hazard analysis,
  • design,
  • implementation,
  • validation,
  • operation,
  • maintenance.

Validation and Reliability Considerations

Hazard and Risk Analysis

Start with:

  • hazards,
  • consequences,
  • required risk reduction.

Do not choose SIL before understanding risk.

Safety vs Security

Functional safety and cybersecurity are different but related.

IEC 61508 does not fully define malicious attack requirements.

IEC points designers toward standards such as:

  • IEC 62443

for cybersecurity.

Safety and Firmware Updates

Any update affecting safety behavior needs:

  • controlled process,
  • verification,
  • validation.

AI and Functional Safety

AI outputs are probabilistic.

Do not make safety depend solely on an unmonitored AI inference.

Use deterministic safety mechanisms.

Example: Motor Drive

Safety functions may include:

  • safe torque off,
  • overspeed protection.

Example: Process Controller

Safety functions may include:

  • high-pressure shutdown,
  • emergency isolation.

Common Mistake: Treating Certification as a Final Test

Functional safety must be built into the full development process.

Common Mistake: Relying on Redundancy Alone

Redundancy without independence may not reduce common-cause risk.

Common Mistake: Ignoring Vendor Safety Constraints

A certified MCU is only useful when integrated according to its safety manual.

Common Mistake: Mixing Safety and Non-Safety Software Without Isolation

A non-safety bug may affect a safety function.

Hardware Safety Workflow

  1. Perform hazard analysis.
  2. Define safety functions.
  3. Determine required SIL.
  4. Select safety-capable semiconductor.
  5. Perform FMEDA.
  6. Design diagnostics.
  7. Define safe state.
  8. Validate fault reaction.
  9. Follow safety lifecycle.
  10. Maintain evidence and configuration control.

Conclusion

Functional safety is not a single MCU feature.

It is a disciplined system-development process.

IEC 61508 requires designers to consider:

  • random hardware failures,
  • systematic failures,
  • diagnostics,
  • safe states,
  • lifecycle controls.

The 2026 revision adds even clearer focus on semiconductor development and integration through IEC 61508-2-1.

The key principle is:

a safety system must detect, tolerate or safely respond to credible failures before those failures create unacceptable risk.

Frequently Asked Questions

IEC 61508 is the foundational international functional-safety standard for electrical, electronic and programmable electronic safety-related systems.

SIL 1 through SIL 4 represent increasing levels of required safety integrity, with SIL 4 being the most stringent.

FMEDA is a structured analysis of hardware failure modes, their effects and the effectiveness of diagnostic mechanisms.

No. The MCU is only one component. The complete system must follow the relevant safety lifecycle, integration constraints and validation process.

The 2026 semiconductor-focused part addresses development and integration requirements for semiconductors, including test libraries, soft IP and integrator deliverables.

References

  1. IEC — IEC 61508-1:2026 Pre-release: https://webstore.iec.ch/en/publication/117296
  2. IEC — IEC 61508-2:2026 Pre-release: https://webstore.iec.ch/en/publication/117297
  3. IEC — IEC 61508-2-1:2026 Semiconductor Requirements: https://webstore.iec.ch/en/publication/117303
  4. IEC — IEC 61508-3:2026 Software Requirements: https://webstore.iec.ch/en/publication/117298
  5. IEC — IEC 61508-6:2026 Application Guidelines: https://webstore.iec.ch/en/publication/117301

Author

Industry Inspire Editorial Team

Editorial team covering industrial automation, manufacturing growth, and B2B strategy.

Share This Article